Volume 2, Issue 2, April 2013, Page: 53-57
Study of CR-39 SSNDs Irradiated with Different Types of Radiation by FTIR Spectroscopy and -Range Determination
Kh. M. Abdel Raouf, Umm Alqura University, KSA.and Zagazig University hospitals, Egypt
Received: Apr. 13, 2013;       Published: May 30, 2013
DOI: 10.11648/j.ajep.20130202.14      View  2938      Downloads  171
Abstract
Studies of CR-39 irradiated with -rays, X-rays and alpha particles by FTIR spectroscopy are presented. In this work we make a comparison between the effect of many types of radiation on the sensitivity of CR-39 detector by using the FTIR spectrometer. It was found that,investigated CR-39 is so sensitive for all types of radiation used that was used as a dosimeter for these types of radiation. The determination of alpha particles range in CR-39 plastic recorder is an important parameter in the field of charged particle identification using Solid State Nuclear Track Detectors. In this work the optical denisty of the detector was calculated and then it is used to determine α-range. An over- etched track profile method and a theoretical method derived by Almasi are compared. A good agreement between the three methods used in α-range determination was found.
Keywords
CR-39, FTIR- Spectroscopy
To cite this article
Kh. M. Abdel Raouf, Study of CR-39 SSNDs Irradiated with Different Types of Radiation by FTIR Spectroscopy and -Range Determination, American Journal of Environmental Protection. Vol. 2, No. 2, 2013, pp. 53-57. doi: 10.11648/j.ajep.20130202.14
Reference
[1]
C. S. Chong uni L. F. Tan, Nucl. Tracks Tadient. Meas, 22, 101-104, (1993).
[2]
M. Varnagy, J. Csokai and S. Szegedi, Nucl. Inst. and Meth. 119, 261-267, (1974).
[3]
S. Charalambous, M. Zamani, Int. J. A l. Ruduat. Isot., 36, 525-529, (1985).
[4]
M. M. Radwan, Rad. Meas., vol. 33, . 183-188, (2001).
[5]
Sangeeta Prasher and Surinder sigh, Rad. Meas., vol. 36, Issue 1-6, . 105-105, (2003).
[6]
R. Schweikani, S, A. Durrani, T. Tsurata, Nucl. Iracks Rudiat. Meas., 22, 153-156, (1993).
[7]
C. S. Chaong, I. Ishak, R. H. Mahata and Y. M. Amin, Radiat. Meas., 28, 119-122, (1997).
[8]
Barillon, R., M. Fromm, A. Chambaudet, R. Katz, J. P. Stoquert, and A. Pape, (1999). Bond scission cross sections for -particles in Cellulose Nitrate (CN). Radiat. Meas., 31, 71-75.
[9]
Chong C. S., I. Ishak, R. H. Mahat, and Y. M. Amin, (1997). UV-Vis and FTIR spectral studies of CR-39 plastics irradiated with X-rays. Radiat. Meas., 28, 119-122.
[10]
Chong, C. S., M. A. C. Chan and L. F. Tan, (1993). The effect of X-ray irradiation on track formation in LR-115 Type II(1999). SSNTD application in science and technology Radiat. Meas., 31, 25-45.
[11]
Gagnadre C., J. L. Decossas and J. C. Vareille, (1993). IR Spectroscopy studies of Poly carbonate irradiated by H+ and Li+ ions. Nucl. Inst. And Meth, 73, 48-52.
[12]
Khan, H. A., I. E. Qureshi, (1999). SSNTD application in science and technology Radiat. Meas., 31, 25-45.
[13]
Meyers R. A., (2003). Encyclopedia of Analatical chemistry, Rantech Ltd, Trazana, C. A. USA.,.
[14]
Saad A. F., S. T. Atwa, N. Yasuda, and M. Fujii, (2001). FTIR spectroscopy of carbon dioxide in CR-39 and SR-90 track detectors irradiated with ions and gamma rays at different energies and fluencies. Radiat. Meas., 34, 51-54.
[15]
M. El-Hofy., H. El-Samman., W. Arafa., Determination of the range of alpha particles in SSNTD by optical density method, Rad. Meas., vol. 31, 241-244, (1999). El-Rahmany, Ph. D. Thesis, unpublished, Nounfia university, (1993).
[16]
Gy Almasi, and Somogyi, G., Atomki Kozlemenyek, vol. 23, 99-112, (1981).
[17]
I Lic, R. and Najzer, M., Image formation in trock-etch detector, Nucl. Tracks Radiat Meas., vol. 17, 453-460 (1990).